7.0.8 Insight Remote Support Monitored Devices Configuration Guide

Monitored Devices Configuration Guide
Chapter 13: Configuring OpenVMS Servers
Note: CPU 0 cannot be removed. If you wish to not have some CPU’s eligible, refer to the
OpenVMS documentation for Indictment Service to learn how to modify this procedure to
meet your needs.
2. Reboot the server for the changes to take effect.
When the Indictment Server is started, there will be an INDICT_SERVER process shown in the SHOW
SYS output:
ES47S3_V8.3>>sho sys
OpenVMS V8.3 on node ES47S3 17-NOV-2008 15:29:15.48 Uptime 0 00:13:01
Pid Process Name State Pri I/O CPU Page flts Pages
0000041C INDICT_SERVER HIB 8 6 0 00:00:00.00 79 95
To enable the Dynamic Processor Resilience Adapter in the Insight RS Console, complete the following
steps:
1. In the Main Menu, select Administrator Settings.
2. Click the Integration Adapters tab.
3. Click the Dynamic Processor Resilience Adapter for HP Integrity servers heading to expand the
adapter pane.
4. Select the Enable Dynamic Processor Resilience Adapter for HP Integrity servers check box.
5. Click Save Adapter Settings.
Insight Remote Support saves the HP SIM Adapter configuration. (Enabled) now appears next to the HP
SIM Adapter to indicate it is enabled.
HP Insight Remote Support (7.0.8)Page 106 of 248