HP Superdome 2 Health Management Stack Whitepaper (September 2011, 5900-2013)

8
Replace the processor. The processor is at physical location
0x0100ff01ff00ff11 enclosure1/blade1/cpusocket0.
Replaceable Unit(s) :
Part Manufacturer : HP
Spare Part No. : AH339-2018A
Part Serial No. : SGH00392GJ
Part Location : 0x0100ff01ff00ff11
enclosure1/blade1/cpusocket0
Additional Info : Core ID:0 , Cache Designator:L3 , Max Core
Frequency (in MHz) = 1866 , L3 cache size (in Kbytes) = 24576 , Stepping = 4
Additional Data :
Severity : Critical
Alert Type : Device Alert
Event Category : Processor
Event Subcategory : Other
Probable Cause : Processor Problem (Internal Machine Error)
Other Event Subcategory : Cache
Event Threshold : 1
Event Time Window : 0 (minutes)
Actual Event Threshold : 1
Actual Event Time Window : 0 (minutes)
Blade Physical Location : 0x0100ff01ffffff94 enclosure1/blade1
Blade Serial Number : MYJ01304MX
OEM System Model : NA
Original Product Number : AH337A
Current Product Number : AH353A
OEM Serial Number : NA
Version Info :
Complex FW Version : 2.50.72
Provider Version : A.1.0.2
Error Log Data :
Error Log Bundle : 45
Onboard Administrator (OA) Web GUI
The HP Superdome 2 OA Web GUI is accessed by pointing a browser at the OA’s IP address and logging
in using a username/password or pre-installed certificate. It displays a photo-realistic view of the system
and installed hardware.
At the top-left of the window is the system status pane, which lists the number of problems present in the
system, categorized by severity. Any FRUs with abnormal health status display a symbol showing the most
severe fault on the FRU. Hovering over a FRU displays the FRU type. Clicking on a FRU loads the status
page for that FRU, and provides tabs to access other information about the FRU.