A.05.80 HP Insight Remote Support Advanced Managed Systems Configuration Guide (June 2013)

Table Of Contents
Managed Systems Configuration Guide
Chapter 13: OpenVMS Server Configuration
5. Apply the changes and close the System Event Analyzer.
Setting the SNMP Protocol in WEBES
If SNMP Agents are installed and configured properly on OpenVMS servers, an SNMP protocol will be
detected and added to the server Management Protocols list in HP SIM after HP SIM discovery.
WEBES 6.1 and 6.2 do not set the SNMP protocol for OpenVMS servers in an Insight Remote Support
Advanced installation, it must be set manually. If SNMP communication to an OpenVMS server is
working and the correct SNMP protocol is assigned in the WEBES Managed Entity Properties page a
CSID will be collected and attached to incidents. Use the following procedure to configure the SNMP
protocol in WEBES:
1. Log on to System Event Analyzer (SEA):
a. On the CMS, click Start Programs Hewlett-Packard Service Tools System Event
Analyzer System Event Analyzer.
Note: If you are logging on to the CMS from another system, open a Web browser and type
the following URL: https://localhost:7906
If localhost does not work, use the Fully Qualified Domain Name or the IP address of the
CMS instead.
b. You will be prompted to enter a Profile User Name for your session; this can be any name you
choose. Enter the name and click Logon.
c. If you are prompted by the browser that the site does not have a signed certificate, click the link
that will let you continue to the web page. This application is hosted on the CMS.
2.
In the SEA interface, click on the Managed Entities button ( ).
3. Select an SNMP protocol that is configured to work with the OpenVMS server, and click Apply
Changes at the bottom of the window.
HP Insight Remote Support Advanced (A.05.80)Page 95 of 204