A.05.80 HP Insight Remote Support Advanced Managed Systems Configuration Guide (June 2013)
Table Of Contents
- Managed Systems Configuration Guide
- Contents
- About This Document
- Insight Remote Support Advanced Managed Systems Overview
- ProLiant Windows Server Configuration
- ProLiant Linux Server Configuration
- ProLiant VMware ESX Server Configuration
- ProLiant VMware ESXi Server Configuration
- Proliant Citrix Server Configuration
- ProLiant c-Class BladeSystem Enclosure Configuration
- Integrity Windows 2003 Server Configuration
- Integrity Windows 2008 Server Configuration
- Integrity Linux Server Configuration
- Integrity Superdome 2 Server Configuration
- HP-UX Server Configuration
- Meeting HP-UX Operating System, Software, and Patch Requirements
- More About WBEM and SFM with Insight Remote Support
- Verifying System Fault Management is Operational
- Creating WBEM Users
- Configuring WEBES to Support WBEM Indications
- Firewall and Port Requirements for HP-UX Managed Systems
- Configuring HP-UX Managed Systems for Proactive Collection Services
- OpenVMS Server Configuration
- Tru64 UNIX Server Configuration
- NonStop Server Configuration
- Enterprise Virtual Array Configuration
- Understanding the Different Server Types and Software Applications
- Command View EVA 8.0.1 and Higher Hosted on the CMS
- Important Port Settings Information
- Important Information Regarding New HP SIM Installations
- Correcting an Existing HP SIM Installation
- Change the WMI Mapper Proxy port in the HP SIM User Interface on the CMS
- Restore Defaults to the wbemportlist.xml file
- Installing and Configuring Command View EVA After HP SIM
- Resetting the Port Numbers when Command View EVA was Installed before HP SIM
- Command View EVA Hosted on a Separate SMS
- Requirements and Documentation to Configure Command View EVA on the SMS
- Overview of Command View EVA 7.0.1 through 8.0.1 with SMI-S Requirements
- SMS System and Access Requirements
- WEBES – EVA Communication
- HP SIM – EVA Communication
- Software Required on the SMS
- Fulfilling ELMC Common Requirements for a Windows SMS
- Installing MC3 on the SMS
- Configuring EVA-Specific Information on the CMS
- Requirements to Support EVA4400 and P6000 with Command View EVA on the ABM
- Enabling User-Initiated Service Mode in Command View EVA 9.3
- Performing a Remote Service Test in Command View EVA 9.3
- Troubleshooting EVA Managed Systems
- P4000 Storage Systems Migration Procedure
- Network Storage System Configuration
- Modular Smart Array Configuration
- Tape Library Configuration
- System Requirements
- Managed Systems Configuration
- Nearline (Tape Library) Configuration
- Secure Key Manager Configuration
- StoreOnce D2D (Disk-to-Disk) Backup System Configuration
- Enterprise Systems Library G3 Configuration
- TapeAssure Service Configuration
- Prerequisites
- Command View for Tape Libraries and TapeAssure Service Installation
- Configure the Command View TL 2.8 CIMOM and TapeAssure Provider
- Configure the Command View TL 3.0 CIMOM and TapeAssure Provider
- HP SIM Device Discovery
- WEBES Configuration
- Create a New SMI-S Protocol in WEBES
- Subscribe to the Command View TL and TapeAssure CIMOM
- SAN Switch Configuration
- E-Series Switch Configuration
- A-Series Switch Configuration
- UPS Network Module Configuration
- Modular Cooling System Configuration
- Glossary
- Index

Chapter 9
Integrity Windows 2008 Server Configuration
This chapter applies only to Windows 2008 Integrity managed systems. Before you can monitor your
Integrity Windows 2008 managed systems you must:
l Verify the managed systems are supported by checking the Insight Remote Support Advanced
Release Notes.
l Verify that WBEM is installed and configured. To determine which version of WBEM Providers your
managed systems require, consult the support matrix at the following URL:
http://h20338.www2.hp.com/integrity/w1/en/os/windows-on-integrity-releases.html.
l Verify connectivity from the managed systems to the CMS.
Verifying WBEM Provider Prerequisites on the
Managed System
For your Windows 2008 Integrity managed system to be discovered by HP SIM and to support Remote
Data Collections, you must have HP Integrity WBEM Providers for Windows Server 2008 installed and
fully configured on your managed systems as directed in the HP SmartSetup product documentation for
the appropriate package. Windows 2008 Integrity managed systems also use WBEM for event
submission/remote monitoring.
Windows Integrity servers shipped by HP manufacturing have the SmartSetup installation files pre-loaded
on the operating system disk. Otherwise the packages can be installed using the SmartSetup CD or
reinstallation media. You can download SmartSetup Providers by visiting
www.hp.com/go/integrity/windows, and then clicking the Integrity Essentials for Windows link under
the Management heading.
Using WBEM Providers
For WBEM Providers to communicate to the CMS, you must provide the WBEM credentials as directed in
the Configuring and Applying WBEM Credentials for Supported managed systems section of the HP
Insight Remote Support Advanced Central Management Server Configuration Guide. These actions must
occur within the HP SIM user interface on the CMS when you are completing the Insight Remote Support
Advanced configuration.
Sending a WBEM Test Indication to Verify
Connectivity
WBEM Providers may be used to send WBEM Indications to verify connectivity.
1. In a Web browser, access the System Management Homepage (SMH) on the managed system:
https://ipaddress:2381.
2. Log on using the administrator user name and password for the managed system.
HP Insight Remote Support Advanced (A.05.80)Page 59 of 204