A.05.80 HP Insight Remote Support Advanced Managed Systems Configuration Guide (June 2013)

Table Of Contents
Managed Systems Configuration Guide
Chapter 6: Proliant Citrix Server Configuration
The trapsink command is required for events to be sent to Insight Remote Support Advanced for
analysis. If the trapsink command is not configured, Insight Remote Support Advanced will not
receive traps.
A rocommunity directive allows SNMP GET and GETNEXT access. It is required for discovery and
by the analysis rules. The format is: rocommunity <community_string>, for example
rocommunity public. The community string used must be the same read community string
configured in the HP SIM and WEBES SNMP protocol assigned to the ProLiant Citrix server. The
rocommunity is used during analysis rules trap processing to retrieve additional information not
supplied with traps.
The rwcommunity directive allows SNMP GET, GETNEXT, and SET access. It is not required for use
by Insight Remote Support Advanced, but may be needed by other applications.
6. For the CMS to collect all relevant information about this managed system, you need to scroll down in
the SNMP Configuration File to the view systemview included entries. The view
systemview included entry allows Insight Remote Support Advanced to read the entire .232 MIB
tree and gather all of the analysis data when events occur. Comment out the default entries with a #
character. Then add this entry:
view systemview included .1 80, and click Change.
HP Insight Remote Support Advanced (A.05.80)Page 46 of 204