Chapter 20: Tape Library Configuration
4. Do one of the following:
n In the right panel, right-click an SNMP trap, and then select Add Trap Entry.
OR
n Select Actions Add Trap Entry.
5. The SNMP Trap Entry dialog box appears.
6. In the Trap Destination field, type the WEBES host IP address or name.
7. Enter public as the Community String unless you have defined another community string.
8. Finally click OK.
Virtual Library System Configuration
To support your Virtual Library System (VLS) Tape Libraries, you need to configure SNMP in Command
View for Virtual Library Systems (VLS).
Use the following procedure to configure SNMP on your VLS Tape Libraries:
1. Log on to the Command View VLS web interface of each VLS node.
2. Click the Notifications tab.
3. Click the Edit SNMP settings task.
4. In the Hostname field, type the WEBES host IP address or name.
5. If you select a non-standard trap community name (i.e. something other than public), verify HP SIM
recognizes this name on the CMS.
6. The trap version is 1.
7. Finally, click Add.
Modular Systems Library G3 Configuration
To support your Modular Systems Library (MSL) G3 Tape Libraries, you need to configure SNMP in
Command View for Modular Systems Libraries (MSL).
Use the following procedure to configure SNMP on your MSL G3 Tape Libraries:
1. Log on to the Command View MSL web interface as Administrator.
2. Click the Configuration tab.
3. Click the Network Management tab.
4. Verify SNMP is selected.
5. In the Ipv4 target address field type the WEBES host IP address.
6. Verify version SNMPv1 is selected.
7. Select Critical and Warning as the filter level.
8. Click Submit.