Chapter 19: Modular Smart Array Configuration
4. From the menu select Configuration Services SNMP Notification.
5. On the Configure SNMP Notification page, modify the SNMP settings to include the CMS as an
SNMP Trap Host and select your Notification Level from the drop-down list (the Informational level
is recommended).
6. Click Apply to commit your changes.
7. Exit the utility and make sure that your P2000 G3 has been discovered by HPSIM.
Configuring a Host-based MSA
A host-based MSA is connected to a host server and managed through a Smart Array Controller. Before
you can monitor a host-based MSA, you must:
l Verify the MSA is supported by checking the Insight Remote Support Advanced Release Notes.
l Verify that the host system is configured as a managed system as directed in its corresponding chapter
of this document.
If the MSA has been configured correctly according to manufacturer's instructions, it should be able to
communicate with the host. If the host has been properly configured as a managed system as directed in
this document, then the host/managed system will be able to communicate the MSA event information to
the CMS for remote support.