A.05.80 HP Insight Remote Support Advanced Managed Systems Configuration Guide (June 2013)

Table Of Contents
Managed Systems Configuration Guide
Chapter 16: Enterprise Virtual Array Configuration
Troubleshooting WBEMDISCO
The wbemdisco.exe tool is a WBEM discovery utility that can be used to verify communications to the
SMI-S CIMOM component. The program is located on the CMS and needs to be run from a command
window.
1. Open a command window on the CMS, change the directory to C:\Program Files\HP\Systems
Insight Manager and run wbemdisco.
Figure 15.11. Running wbemdisco
2. This will launch another window, enter the name for your SMS node. This Profile name and settings
are maintained for future use.
Figure 15.12. SMI-S Test Tool
3. Enter the IP address for the SMS node (Port 5989 is the default port for SMI-S).
4. For the Interop Namespace designation use root/PG_InterOP; the User Name should be
administrator; default Password should be administrator. If you used cimuser to create a
different username/password use those values instead.
This step changes for Command View EVA 8. The Interop Namespace designation is interop and
the User Name and Password credentials are the same as the Command View EVA login.