A.05.80 HP Insight Remote Support Advanced Managed Systems Configuration Guide (June 2013)

Table Of Contents
Managed Systems Configuration Guide
Chapter 16: Enterprise Virtual Array Configuration
3. Save the file.
4. Restart the HP SIM service.
Re-identify all WBEM/WMI systems in HP SIM to correct the port references by selecting Options
Identify Systems.
Installing and Configuring Command View EVA After
HP SIM
The Command View EVA installation kit includes SMI-S as a component. At installation time only, SMI-S
assigns two ports. The default ports SMI-S will assign if they are available are:
l http port=5988
l https port=5989
If one or both of these ports are in use, the installation will provide an additional configuration screen that
allows the port numbers to be changed. The SMI-S installer will suggest port 60000 if it is not in use. SMI-
S will retain port 5988 if it there is no conflict. These are the ports that SMI-S will use when the process HP
StorageWorks CIM Object Manager starts.
HP Insight Remote Support Advanced (A.05.80)Page 110 of 204