A.05.70 HP Insight Remote Support Advanced Managed Systems Configuration Guide (October 2011, 5900-1726)

Managed Systems Configuration Guide
Chapter 17: P4000 Storage Systems Migration Procedure
13. To verify that the P4000 Storage System(s) are communicating with the CMS, open CMC and select
at least one storage node and send a test trap to the CMS. Select SNMP in the left menu tree and
open the SNMP Traps tab. In the SNMP Trap Tasks drop-down list, select Send Test Trap.
Note: Note that in CMC 9.0 and higher, SNMP traps are configured at the Management Group
level, not at the node level.
Go to CMS configurations to verify that the test event was posted to the CMS logs. The CMC read-
only credentials were verified during device discovery when each SAN/iQ device was added to CMS
monitored listed.
HP Insight Remote Support Advanced (A.05.70)Page 154 of 199