HP Insight Management WBEM Smart Array Provider for Linux Datasheet
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualSerialNumber
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
SystemVirtualUUID
HP_HardwareIndication
Enclosure Location string
HWLogicalLocation
For example: Port 1I Box 1
Enclosure Serial Number
HWSerialNumber
HP_DeviceIndication
Enclosure Model string
DeviceModel
HP_DeviceIndication: Enclosure Fan Status changed to Degraded
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
3 (Warning)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Storage Enclosure Fan status has changed
to Degraded. An enclosure has detected
Description
there may a problem with one or more of
the fans.
WBEM Path of SMX_SAStorageEnclosureProcessorAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
305EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
Ensure that the system is adequately
ventilated. Check for proper room
RecommendedActions
temperature and internal/external airflow.
Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Fan status DegradedSummary
24 (Primary Storage Cooling)EventCategory
94 (Fan failure)ProbableCause
Fan DegradedProbableCauseDescription
Provider Indications 81