HP Insight Management WBEM Smart Array Provider for Linux Datasheet
HP_DeviceIndication
Enclosure Model string
DeviceModel
HP_DeviceIndication: Enclosure Temperature sensor Status
Changed to Critical
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
5 (major)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Storage Enclosure Temperature sensor
status has changed to Critical. An
Description
enclosure temperature is reaching the
maximum allowed temperature for normal
operation. A shutdown is imminent. Action
is required before loss of data occurs.
WBEM Path of SMX_SAStorageEnclosureProcessorAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
309EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
Ensure that the system is adequately
ventilated. Check for proper room
RecommendedActions
temperature and internal/external airflow.
Add or repair fans and air baffling if
necessary.
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Temperature sensor status Critical
Summary
24 (Primary Storage Cooling)EventCategory
51 (Temperature Unacceptable )ProbableCause
Temperature Status Changed to CriticalProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion