HP Insight Management WBEM Smart Array Provider for Linux Datasheet

Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
SystemVirtualUUID
HP_HardwareIndication
Enclosure Location string
HWLogicalLocation
For example: Port 1I Box 1
Enclosure Serial Number
HWSerialNumber
HP_DeviceIndication
Enclosure Model string
DeviceModel
HP_DeviceIndication: Enclosure Power Supply Status changed to
Redundant Degraded
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
3 (Warning)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Storage Enclosure Power Subsystem status
has changed to Degraded Redundancy.
Description
WBEM Path of SMX_SAStorageEnclosureProcessorAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
303EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
Check status of all enclosure power
supplies. Ensure that power supplies have
RecommendedActions
not failed. Add or replace power supplies
as necessary.
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Power supply status Redundant DegradedSummary
17 (Primary Storage Power)EventCategory
89 (Power supply failure)ProbableCause
Redundant Power Supply DegradedProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType