HP Insight Management WBEM Smart Array Provider for Linux Datasheet
Model name of the computer system generating the
indication
SystemModel
Platform GUID of the computer system generating the
indication
SystemGUID
3 (Enclosure) for c-Class blade systemsImpactedDomain
4 (System) for all other systems
NOTE: When ImpactedDomain is 3 (Enclosure) the
properties that follow and are indicated with an asterisk
(*) below will be populated.
HP_BladeCSLocation.LocationInformation[0]BladeBay *
HP_ComputerSystem.NameBladeName *
HP_BladeEnclosureCS.NameEnclosureName *
Rack name if one exists
RackName *
Rack Unique Identifier if one exists
RackUID *
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualSerialNumber
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
SystemVirtualUUID
HP_HardwareIndication
Enclosure Location string
HWLogicalLocation
For example: Port 1I Box 1
Enclosure Serial Number
HWSerialNumber
HP_DeviceIndication
Enclosure Model string
DeviceModel
HP_DeviceIndication: Enclosure Power Supply Status changed to
OK (Redundant)
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
2 (Info)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Storage Enclosure Power Subsystem has
changed to Fully Redundant.
Description
WBEM Path of SMX_SAStorageEnclosureProcessorAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
302EventID
Provider Indications 71