HP Insight Management WBEM Smart Array Provider for Linux Datasheet
HP_DeviceIndication: Enclosure Power Supply Status changed to
Non Redundant
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
3 (Warning)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Storage Enclosure Power Subsystem status
has changed to non-redundant.
Description
WBEM Path of SMX_SAStorageEnclosureProcessorAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
301EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
Check status of all enclosure power
supplies. Ensure that power supplies have
RecommendedActions
not failed. Add or replace power supplies
as necessary.
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Power Supply status Non-RedundantSummary
17 (Primary Storage Power)EventCategory
89 (Power Supply Failure)ProbableCause
Redundant Power Supply Status Changed to
Non-Redundant
ProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion
Firmware version of the computer system generating the
indication
SystemFirmwareVersion
Serial number of the computer system generating the
indication
SystemSerialNumber
Product ID of the computer system generating the
indication
SystemProductID