HP Insight Management WBEM Smart Array Provider for Linux Datasheet
For example: Smart Array in Slot 3 if
controller is in a PCI slot.
CIM_ManagedSystemElement
Status for Array Controller.
OperationalStatus[0]
0 (Unknown)
2 (OK)
6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
2 (Enabled)EnabledDefault
5 (Not Applicable)EnabledState
12 (Not Applicable)RequestedState
CIM_System
SMX_SAArrayControllerCreationClassName
Controller Serial Number.
Name
EMBEDDED-<id> will be reported if there is no Serial
Number. For example: embedded on motherboard.
PCISLOT-<Slot number> will be reported if there is
no Serial Number and the controller is in a PCI slot where
Slot number is the number of PCI slot.
OtherNameFormat
CIM_ComputerSystem
Dedicated[0]Dedicated
0 (Not Dedicated)
HPSA_Arraycontroller
See HP Smart Array Profile
ADGSupported
See HP Smart Array Profile
BatteryStatus
See HP Smart Array Profile
CacheBoardPresent
See HP Smart Array Profile
CacheHasBattery
See HP Smart Array Profile
CacheParityReadErrors
See HP Smart Array Profile
CacheParityWriteErrors
See HP Smart Array Profile
CacheReadPercent
See HP Smart Array Profile
CacheSerialNumber
See HP Smart Array Profile
CacheSizeTotal
See HP Smart Array Profile
CacheState
See HP Smart Array Profile
CacheStatus
See HP Smart Array Profile
CacheWritePercent
See HP Smart Array Profile
ControllerStatus
See HP Smart Array Profile
ExpandPriority
Using the Provider 7