HP Insight Management WBEM Smart Array Provider for Linux Datasheet
5 (Device Alert)AlertType
10EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
No action is recommended.RecommendedActions
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Array controller cache status temporarily
disabled
Summary
6 (Primary Storage)EventCategory
35 (Performance Degraded)ProbableCause
Array Controller Cache Status Changed to
Temporarily Disabled
ProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion
Firmware version of the computer system generating the
indication
SystemFirmwareVersion
Serial number of the computer system generating the
indication
SystemSerialNumber
Product ID of the computer system generating the
indication
SystemProductID
Model name of the computer system generating the
indication
SystemModel
Platform GUID of the computer system generating the
indication
SystemGUID
3 (Enclosure) for c-Class blade systemsImpactedDomain
4 (System) for all other systems
NOTE: When ImpactedDomain is 3 (Enclosure) the
properties that follow and are indicated with an asterisk
(*) below will be populated.
HP_BladeCSLocation.LocationInformation[0]BladeBay *
HP_ComputerSystem.NameBladeName *
HP_BladeEnclosureCS.NameEnclosureName *
Rack name if one exists
RackName *
Rack Unique Identifier if one exists
RackUID *
Provider Indications 67