HP Insight Management WBEM Smart Array Provider for Linux Datasheet
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion
Firmware version of the computer system generating the
indication
SystemFirmwareVersion
Serial number of the computer system generating the
indication
SystemSerialNumber
Product ID of the computer system generating the
indication
SystemProductID
Model name of the computer system generating the
indication
SystemModel
Platform GUID of the computer system generating the
indication
SystemGUID
3 (Enclosure) for c-Class blade systemsImpactedDomain
4 (System) for all other systems
NOTE: When ImpactedDomain is 3 (Enclosure) the
properties that follow and are indicated with an asterisk
(*) below will be populated.
HP_BladeCSLocation.LocationInformation[0]BladeBay *
HP_ComputerSystem.NameBladeName *
HP_BladeEnclosureCS.NameEnclosureName *
Rack name if one exists
RackName *
Rack Unique Identifier if one exists
RackUID *
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualSerialNumber
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
SystemVirtualUUID
HP_HardwareIndication
Array Controller firmware version string
HWFirmwareVersion
Array Controller Location string
HWLogicalLocation
For example: Smart Array P600 in Slot 5
SAEnclosureFirmwareHWManufacturer
Array Controller Serial Number
HWSerialNumber
HP_DeviceIndication
Array Controller Model string
DeviceModel
HP_DeviceIndication: Controller Redundancy has been lost
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
56