HP Insight Management WBEM Smart Array Provider for Linux Datasheet

Array Controller Location string
HWLogicalLocation
For example: Smart Array P600 in Slot 5
Array Controller Manufacturer
HWManufacturer
Array Controller Serial Number
HWSerialNumber
HP_DeviceIndication
Array Controller Model string
DeviceModel
HP_DeviceIndication: Controller Redundancy state has been set
to Active
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
3 (Warning)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Smart Array controller redundancy state
has changed from Standby to Active.
Description
WBEM Path to SMX_SAArrayController class.AlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
3EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
Check status of all controllers. An array
controller may have failed causing this
controller to become active.
RecommendedActions
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Controller redundancy state set to ActiveSummary
6 (Primary Storage)EventCategory
1 (Other)ProbableCause
Array Controller Redundancy State Changed
to Active
ProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
Provider Indications 55