HP Insight Management WBEM Smart Array Provider for Linux Datasheet

3 (Enclosure) for c-Class blade systemsImpactedDomain
4 (System) for all other systems
NOTE: When ImpactedDomain is 3 (Enclosure) the
properties that follow and are indicated with an asterisk
(*) below will be populated.
HP_BladeCSLocation.LocationInformation[0]BladeBay *
HP_ComputerSystem.NameBladeName *
HP_BladeEnclosureCS.NameEnclosureName *
Rack name if one exists
RackName *
Rack Unique Identifier if one exists
RackUID *
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualSerialNumber
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
SystemVirtualUUID
HP_HardwareIndication
Array Controller firmware version string
HWFirmwareVersion
Array Controller Location string
HWLogicalLocation
For example: Smart Array P600 in Slot 5
Array Controller Manufacturer
HWManufacturer
Array Controller Serial Number
HWSerialNumber
HP_DeviceIndication
Array Controller Model string
DeviceModel
HP_DeviceIndication: Controller Status Changed to ERROR
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
5 (Major)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A Smart Array controller status has changed
to Error.
Description
WBEM Path to SMX_SAArrayController class.AlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
2EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart Array (ProviderName
Provider Indications 53