HP Insight Management WBEM Smart Array Provider for Linux Datasheet
SMX_SAStorageVolumeIndication: Logical Drive Status Changed
to Degraded
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
2 (Info)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A logical drive is in a degraded state.
Device is still servicing I/O but
redundancy may be degraded or lost.
Description
WBEM Path of SMX_SAStorageVolume classAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
103EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
Check status of physical drives. Degraded
status may be caused by failed or missing
RecommendedActions
physical drives, or a data recovery
operation on one or more physical drives.
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Logical drive in degraded stateSummary
6 (Primary Storage)EventCategory
86 (Disk Failure)ProbableCause
Logical State Changed to DegradedProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion
Firmware version of the computer system generating the
indication
SystemFirmwareVersion
Serial number of the computer system generating the
indication
SystemSerialNumber
Product ID of the computer system generating the
indication
SystemProductID
50