HP Insight Management WBEM Smart Array Provider for Linux Datasheet

Physical Disk Model string
DeviceModel
Controller Location
DeviceControllerLogicalLocation
For example: SmartArray 642 in Slot 2
HPSA_StorageVolumeIndication : Logical Drive Status Changed
to OK
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
2 (Informational)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A logical drive status has changed from a
non-OK state to OK.
Description
WBEM Path of SMX_SAStorageVolume ClassAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
101EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
No action is recommended.RecommendedActions
Name of the computer system generating the indicationSystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Logical drive status OKSummary
6 (Primary Storage)EventCategory
1 (Other)ProbableCause
Logical Drive Status Changed to OKProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion
Firmware version of the computer system generating the
indication
SystemFirmwareVersion
Serial number of the computer system generating the
indication
SystemSerialNumber
46