HP Insight Management WBEM Smart Array Provider for Linux Datasheet

Platform GUID of the computer system generating the
indication
SystemGUID
3 (Enclosure) for c-Class blade systemsImpactedDomain
4 (System) for all other systems
NOTE: When ImpactedDomain is 3 (Enclosure) the
properties that follow and are indicated with an asterisk
(*) below will be populated.
HP_BladeCSLocation.LocationInformation[0]BladeBay *
HP_ComputerSystem.NameBladeName *
HP_BladeEnclosureCS.NameEnclosureName *
Rack name if one exists
RackName *
Rack Unique Identifier if one exists
RackUID *
Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualSerialNumber
Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
SystemVirtualUUID
HP_HardwareIndication
Physical Disk firmware version string
HWFirmwareVersion
Physical Disk Location string
HWLogicalLocation
For example: Port:1E Box: 1 Bay 5
Physical Location of the Failed Drive (Bay Number)
HWPhysicalLocation
Physical Disk Serial Number
HWSerialNumber
HP_DeviceIndication
Physical Disk Model string
DeviceModel
Controller Location
DeviceControllerLogicalLocation
For example: SmartArray 642 in Slot 2
HP_DeviceIndication: Physical Drive Status Changed to
REBUILDING
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
2 (Informational)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A physical drive status has changed to
Rebuilding. Data is now being rebuilt onto
this drive from the RAID set.
Description
WBEM Path of SMX_SADiskDrive classAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
42