HP Insight Management WBEM Smart Array Provider for Linux Datasheet
HP_DeviceIndication: Physical Drive Status Changed to ERROR
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
Severity
PerceivedSeverity
5 (Major)
Time of indication
IndicationTime
CIM_AlertIndication
A physical drive status has changed to
Error.
Description
WBEM Path of SMX_SADiskDrive classAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
202EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart Array (ProviderName
Check for failed or removed physical
drives.
RecommendedActions
Name of the computer system generating the indication
SystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Physical drive status ErrorSummary
6 (Primary Storage)EventCategory
86 (Disk Failure)ProbableCause
Physical Drive Status Changed to ErrorProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
OSVersion
For example: 2.2.0.0ProviderVersion
Firmware version of the computer system generating the
indication
SystemFirmwareVersion
Serial number of the computer system generating the
indication
SystemSerialNumber
Product ID of the computer system generating the
indication
SystemProductID
Model name of the computer system generating the
indication
SystemModel
Provider Indications 41