HP Insight Management WBEM Smart Array Provider for Linux Datasheet
SMX_SAStorageEnclosureEnclosureLocation (Association)
The following table lists the associations implemented for this class.
Property ImplementationProperty Name
SMX_SAStorageEnclosureElement
SMX_SAStorageEnclosureLocationPhysicalLocation
Provider Indications
The following tables describe the SMX WBEM Smart Array Provider
indications that are implemented for HP ProLiant server platforms where
available.
Indications Generated by the Provider
HP_DeviceIndication: Physical Drive Status Changed to OK
Property ImplementationProperty Name
CIM_Indication
GUID string generated at the time of indication
IndicationIdentifier
2 (Informational)PerceivedSeverity
Time of indication
IndicationTime
CIM_AlertIndication
A physical drive status has changed from
a non-OK state to OK.
Description
WBEM Path of SMX_SADiskDrive classAlertingManagedElement
2 (CIMObjectPath)AlertingElementFormat
5 (Device Alert)AlertType
201EventID
Time of the event or time of the indication if event time
unknown
EventTime
HP Smart ArrayProviderName
No action is recommended.RecommendedActions
Name of the computer system generating the indicationSystemName
CreationClassName of the computer system generating
the indication
SystemCreationClassName
HP_AlertIndication
Physical Drive status OKSummary
6 (Primary Storage)EventCategory
1 (Other)ProbableCause
Physical Drive Status Changed to OKProbableCauseDescription
Contains a list of all the IP addresses of the computer
system generating the indication
NetworkAddresses
SMX_OperatingSystem.OSTypeOSType
Provider Indications 39