HP Insight Management WBEM Smart Array Provider for Linux Datasheet
The following table lists the properties implemented.
Property ImplementationProperty Name
CIM_ManagedElement
For Primodial Pools:
ElementName
Controller name and location
Smart Array Embedded Controller=7, where 7 is
an internal identifier of the embedded controller.
For example: Smart Array in Slot 3 if
controller is in a PCI slot.
For Concrete Pools:
Controller name and location:Array identifier
For example: Smart Array in Slot 3 if
controller is in a PCI slot. Array - 0 for
internal
CIM_Capabilities
Key: Opaque key
InstanceID
CIM_StorageCapabilities
1 (When number of drives is an odd number)DataRedundancyDefault
2 (When number of drives is an even number – For
example: Pool can be configured for mirroring)
1 (When number of drives is an odd number)DataRedundancyMax
2 (When number of drives is an even number – For
example: Pool can be configured for mirroring)
0DataRedundancyMin
0DeltaReservationDefault
0DeltaReservationMax
0DeltaReservationMin
5 (Storage Pool)ElementType
True - When number of drives > 1 (For example: Pool
can be configured for redundancy)
NoSinglePointOfFailure
False – When number of drives <= 1
True - When number of drives > 1 (For example: Pool
can be configured for redundancy)
NoSinglePointOfFailureDefault
False – When number of drives <= 1
0 (When number of drives <= 1)PackageRedundancyDefault
1 (When number of drives = 2 or 3)
2 (When number of drives > 3)
0 (When number of drives <= 1)PackageRedundancyMax
1 (When number of drives = 2 or 3)
2 (When number of drives > 3)
28