HP Insight Management WBEM Smart Array Provider for Linux Datasheet

SMX_SAStoragePool Class
The SMX_SAStoragePool class implements the HPSA_StoragePool class and represents any
concrete storage pools created on an array controller. There is one instance per array system.
The following table lists the properties implemented.
Property ImplementationProperty Name
CIM_ManagedElement
Controller name and location: pool identifier
ElementName
Smart Array Embedded Controller=7, where 7 is
an internal identifier of the embedded controller.
For example: Smart Array in Slot 3: Array 0
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
Opaque key
InstanceID
Controller serial number: <n> where n is the
array number as supplied from API.
PoolID
Always set to FALSEPrimordial
Remaining raw space in current pool
RemainingManagedSpace
Total raw space managed by this pool
TotalManagedSpace
HPSA_StoragePool
SMX_SAMediaAccessStatData Class
The SMX_SAMediaAccessStatData class implements the HPSA_MediaAccessStatData
and represents the Monitoring and Performance data counters on HP Disk Drives.
The following table lists the properties implemented.
Property ImplementationProperty Name
CIM_ManagedElement
CIM_StatisticalData
Opaque key
InstanceID
0SampleInterval
CIM_MediaAccessStatData
HPSA_MediaAccessStatData
See HP Smart Array Profile
AbortedCommands
See HP Smart Array Profile
BadTargetErrors
See HP Smart Array Profile
DRQTimeouts
See HP Smart Array Profile
ECCRecoveredReadErrors
Disk location
ElementName
For example: Port: 1E Box 1 Bay: 5
See HP Smart Array Profile
FailedReadRecovers