HP Insight Management WBEM Smart Array Provider for Linux Datasheet

TargetType valueElementName
CIM_ManagedSystemElement
Storage Enclosure Processor FirmwareName
CIM_LogicalElement
Storage Enclosure Processor FirmwareCaption
Storage Enclosure Processor FirmwareDescription
CIM_SoftwareIdentity
Storage Enclosure Processor FirmwareClassificationDescriptions[0]
10 (Firmware)Classifications[0]
Opaque key
InstanceID
Enclosure Vendor string
Manufacturer
CIM:SoftwareFamilyIdentityInfoType
HPQ:<TargetType value>IdentityInfoValue
Enclosure firmware string
VersionString
HPSA_EnclosureFirmware
SMX_SAPrimordialPool Class
The SMX_SAPrimordialPool class implements the HPSA_PrimordialPool class and
represents the total raw storage managed by the array controller. There is one instance per array
system.
The following table lists the properties implemented.
Property ImplementationProperty Name
CIM_ManagedElement
Controller name and location: pool identifier
ElementName
Smart Array Embedded Controller=7, where 7 is
an internal identifier of the embedded controller.
For example: Smart Array in Slot 3: Primordial
Pool
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
Opaque key
InstanceID
Controller serial number
PoolID
Always set to TRUEPrimordial
Remaining raw space on controller. This is calculated by
summing the remaining space on all drives attached to
the controller.
RemainingManagedSpace
Total raw space available to controller. This is calculated
by summing the total space on all drives connected to this
controller.
TotalManagedSpace
HPSA_PrimordialPool
18