HP Insight Management WBEM Smart Array Provider for Linux Datasheet HP Integrity and HP ProLiant Servers HP Part Number: 5900-0018 Published: June 2009 Edition: Edition: 1
© Copyright 2009 Hewlett-Packard Development Company, L.P. Legal Notice Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
HP Insight Management WBEM Smart Array Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Smart Array provider describes both host-based Smart Array Host Bus Adapters (HBA). This provider implementation excludes externally attached Modular Smart ArrayMSA devices (for example, MSA500) and excludes fibre attached devices (for example, MSA1000 or MSA1500.
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 4 SMX_SAMediaAccessStatData SMX_SAStorageSetting SMX_SADriveCage SMX_SASCSIProtocolEndpoint SMX_SASCSIProtocolController SMX_SARedundancySet SMX_SAStorageRedundancySet SMX_SAStorageSpecificCollection SMX_SADriveCageLocation SMX_SAArraySystemLocation SMX_SADiskDriveLocation SMX_SAArrayControllerLocation SMX_SAStorageCapabilities SMX_SAProduct SMX_SAStorageEnclosureLocation SMX_SAArraySystemRedundancyS
• • • • • • • • • • • • • SMX_SASpareExtentStorageRedundancySet (Association) SMX_SAStorageExtentStorageVolume (Association) SMX_SADAPortSCSIProtocolEndpoint (Association) SMX_SAStorageGroupHostedCollection (Association) SMX_SAPhysicalPackageArraySystem (Association) SMX_SAArrayControllerPhysicalPackageArrayController (Association) SMX_SADiskDriveMediaAccessStatData (Association) SMX_SAArrayControllerPhysicalPackageArrayControllerLocation (Association) SMX_SAPhysicalPackageArraySystemLocation (Association)
For example: Logical Drive Failure For example: Physical Drive Degraded/Failed CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SAArraySystem Name Controller Serial Number EMBEDDED- will be reported if there is no Serial Number for device is local For example: embedded on motherboard.
For example: Smart Array in Slot 3 if controller is in a PCI slot. CIM_ManagedSystemElement OperationalStatus[0] Status for Array Controller. 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SAArrayController Name Controller Serial Number. EMBEDDED- will be reported if there is no Serial Number. For example: embedded on motherboard.
NumberOfPorts See HP Smart Array Profile RebuildPriority See HP Smart Array Profile SMX_SAStorageVolume Class The SMX_SAStorageVolume class implements the HPSA_StorageVolume class and represents the Logical Volumes configured on the Smart Array. The following table lists the properties implemented.
2 (RAID 6) CIM_Storagevolume 2 (VPD83NAA6) NameFormat HPSA_Storagevolume Accelerator See HP Smart Array Profile Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OperationalStatus[0, 1] Volume status. DMTF defined value will be populated in index[0] and extended status will be populated in index[1] per HP Smart Array Profile. OSName Corresponding OS name for this volume.
TotalPowerOnHours Number of service hours logged for the drive CIM_MediaAccessDevice CIM_DiskDrive HPSA_DiskDrive DriveConfiguration See HP Smart Array Profile DriveHasMNPData See HP Smart Array Profile DriveInterface See HP Smart Array Profile DrivePlacement See HP Smart Array Profile DriveRotationalSpeed See HP Smart Array Profile NegotiatedDataWidth See HP Smart Array Profile NegotiatedSpeed See HP Smart Array Profile Identify() See HP Smart Array Profile SMX_SAStorageExtent Class The S
CIM_StorageExtent BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive ExtentStatus[0] This will indicate extended status for the disk drive Possible values: 2 (None) 11 (Rebuild – disk drive is currently rebuilding data) NumberOfBlocks Total number of blocks on disk drive Primordial Set to True TotalPowerOnHours Total service hours reported disk drive HPSA_StorageExtent SMX_SADiskDriveFirmware Class The SMX_SADiskDriveFirmware class implements the HPSA_DiskDriveFi
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName . Refer to “Physical Location” (page 84) for more information.
N/A – Not Available for this implementation Version CIM_PhysicalPackage 2 (Not Applicable) RemovalConditions HPSA_ ArrayControllerPhysicalPackage SMX_SADiskPhysicalPackage Class The SMX_SADiskPhysicalPackage class represents the physical aspects of the disk drive. There is one instance per disk drive. The following table lists the properties implemented.
Port: Box: where m is the port and n is the box number. Name CIM_PhysicalElement CreationClassName SMX_SAStorageEnclosure Manufacturer Enclosure vendor string For example: HP For example: N/A if not available Enclosure model string Model For example: PROLIANT 6L6I For example: N/A if not available PartNumber N/A – Not Available in this implementation SerialNumber Enclosure Serial Number. N/A will be reported if there is no serial number (For example: internal enclosures).
0 (Unknown) 2 (OK) 3 (Degraded) 6 (Error) Index[1] – Fan status (See Profile) Index[2] – Power Supply status (See Profile) Index[3] – Temp Sensor Status (See Profile) NOTE: Operational status for Fan, Power and Temp Sensor will be not detectedfor internal storage enclosure(s) of the local controller(s) For example: PCI or Embedded.
CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SAPortController DeviceID Controller serial number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.
CIM_LogicalDevice CreationClassName SMX_SADAPort DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_LogicalPort 2 (Front-End Only) UsageRestriction CIM_DAPort HPSA_DAPort SMX_SAFirmware Class The SMX_SAFirmware class implements the HPSA_Firmware class and represents the firmware installed on a Smart Array controller. The following table lists the properties implemented.
TargetType value ElementName CIM_ManagedSystemElement Name Storage Enclosure Processor Firmware CIM_LogicalElement Caption Storage Enclosure Processor Firmware Description Storage Enclosure Processor Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Processor Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: VersionString Enclosure f
SMX_SAStoragePool Class The SMX_SAStoragePool class implements the HPSA_StoragePool class and represents any concrete storage pools created on an array controller. There is one instance per array system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and location: pool identifier ElementName Smart Array Embedded Controller=7, where 7 is an internal identifier of the embedded controller.
FailedWriteRecovers See HP Smart Array Profile FormatErrors See HP Smart Array Profile HardReadErrors See HP Smart Array Profile HardwareErrors See HP Smart Array Profile HardWriteErrors See HP Smart Array Profile HotPlugCount See HP Smart Array Profile MediaFailures See HP Smart Array Profile NotReadyErrors See HP Smart Array Profile OtherTimeOuts See HP Smart Array Profile SCSIBusFaults See HP Smart Array Profile SectorsRead See HP Smart Array Profile SectorsWritten See HP Smart Arr
2 (RAID 1+0) DataRedundancyMin 1 (RAID 0, RAID 5, RAID 6) 2 (RAID 1+0) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 NoSinglePointOfFailure False – RAID 0 True – RAID 1+0, RAID 5, RAID 6 PackageRedundancyGoal 0 (RAID 0) 1 (RAID 1+0, RAID 5) 2 (RAID 6) PackageRedundancyMax 0 (RAID 0) 1 (RAID 1+0, RAID 5) 2 (RAID 6) PackageRedundancyMin 0 (RAID 0) 1 (RAID 1+0, RAID 5) 2 (RAID 6) HPSA_StorageSetting SMX_SADriveCage Class The SMX_SADriveCage class implements the HPSA_DriveCa
N/A – Not available in this implementation Version CIM_PhysicalPackage 2 (Not Applicable) RemovalConditions HP_DriveCage BackplaneSpeed See HP Smart Array profile DriveBays See HP Smart Array profile DuplexLocation See HP Smart Array profile HPSA_DriveCage SMX_SASCSIProtocolEndpoint Class The SMX_SASCSIProtocolEndpoint class implements the HPSA_SCSIProtocolEndpoint class and represents an access point to storage resources. The following table lists the properties implemented.
4 (Both Initiator and Target) HPSA_SCSIProtocolEndpoint SMX_SASCSIProtocolController Class The SMX_SASCSIProtocolController class implements the HPSA_SCSIProtocolController class and represents a view a SCSI resources on the array controller. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName Controller name and location Smart Array Embedded Controller=7, where 7 is an internal identifier of the embedded controller.
The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Storage Array Consolidated Status Description Storage Array Consolidated Status ElementName Storage Array Consolidated Status CIM_Collection CIM_SystemSpecificCollection Opaque key InstanceID HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Consolidated status for all array controllers. Refer to section 9.
SMX_SAArraySystemLocation Class The SMX_SAArraySystemLocation class implements the HPSA_ArraySystemLocation class and represents a location string for the array system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Smart Array in Refer to “Physical Location” (page 84) for more information. Description Same as Caption. ElementName Same as Caption.
Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number of Disk Drive - When ‘Bay’ is specified in ElementLocationTagDesc. ElementLocationTagDesc 20 (Bay)– when firmware supports Bay numbering HPSA_DiskDriveLocation SMX_SAArrayControllerLocation Class The SMX_SAArrayControllerLocation class implements the HPSA_ArrayControllerLocation class and represents a location string for the array controller. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName For Primodial Pools: Controller name and location Smart Array Embedded Controller=7, where 7 is an internal identifier of the embedded controller. For example: Smart Array in Slot 3 if controller is in a PCI slot. For Concrete Pools: Controller name and location:Array identifier For example: Smart Array in Slot 3 if controller is in a PCI slot.
PackageRedundancyMin 0 HPSA_StorageCapabilities SMX_SAProduct Class The SMX_SAProduct class implements the HPSA_Product class and represents the top level marketing information for the array system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Controller name and location ElementName Smart Array Embedded Controller=7, where 7 is an internal identifier of the embedded controller.
ElementLocationTagDesc 19 (Box) HPSA_StorageEnclosureLocation SMX_SAArraySystemRedundancySet (Association) The following table lists the associations implemented for this class. Property Name Property Implementation SameElement SMX_SARedundancySet SystemElement SMX_SAArraySystem SMX_SAStorageVolumeStorageSetting (Association) The following table lists the associations implemented for this class.
SMX_SAArraySystemSCSIProtocolController (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SASCSIProtocolController SMX_SAArraySystemPortController (Association) The following table lists the associations implemented for this class.
SMX_SAArraySystemDAPort (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SADAPort SMX_SAArraySystemPrimordialPool (Association) The following table lists the associations implemented for this class.
SMX_SAProductPhysicalPackage (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAProduct PartComponent SMX_SAPhysicalPackage SMX_SAStorageEnclosureDriveCage (Association) The following table lists the associations implemented for this class.
SMX_SAStoragePoolStorageExtent (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAStoragePool PartComponent SMX_SAStorageExtent SMX_SAPrimordialPoolStorageExtent (Association) The following table lists the associations implemented for this class.
SMX_SASCSIProtocolControllerStorageVolume (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SASCSIProtocolController Dependent SMX_SAStorageVolume DeviceAccess 2 (Read Write) DeviceNumber Device LUN number SMX_SAFirmwareArraySystem (Association) The following table lists the associations implemented for this class.
SMX_SADiskDriveStorageExtent (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SADiskDrive Dependent SMX_SAStorageExtent SMX_SADiskPhysicalPackageDiskDrive (Association) The following table lists the associations implemented for this class.
SMX_SAStorageExtentStorageVolume (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageVolume SMX_SADAPortSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class.
SMX_SADiskDriveMediaAccessStatData (Association) The following table lists the associations implemented for this class. Property Name Property Implementation ManagedElement SMX_SADiskDrive Stats SMX_SAMediaAccessStatData SMX_SAArrayControllerPhysicalPackageArrayControllerLocation (Association) The following table lists the associations implemented for this class.
SMX_SAStorageEnclosureEnclosureLocation (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Element SMX_SAStorageEnclosure PhysicalLocation SMX_SAStorageEnclosureLocation Provider Indications Indications Generated by the Provider The following tables describe the SMX WBEM Smart Array Provider indications that are implemented for HP ProLiant server platforms where available.
OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
HP_DeviceIndication: Physical Drive Status Changed to ERROR Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity Severity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Error.
SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
AlertType 5 (Device Alert) EventID 203 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions No action is recommended. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive is now rebuilding.
SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string HWLogicalLocation Physical Disk Location string For example: Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerial
EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Predictive Failure. NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
DeviceModel Physical Disk Model string DeviceControllerLogicalLocation Controller Location For example: SmartArray 642 in Slot 2 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed from a non-OK state to OK.
SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed to Error.
SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost.
SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP_DeviceIndication: Controller Status Changed to OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed from non-OK to OK. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
3 (Enclosure) for c-Class blade systems ImpactedDomain 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
RecommendedActions Check controller status and run diagnostics.
HWLogicalLocation Array Controller Location string For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number HP_DeviceIndication Array Controller Model string DeviceModel HP_DeviceIndication: Controller Redundancy state has been set to Active Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indicat
OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller has detected that redundancy has been lost due to failure or loss of communication with partner controller. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller redundancy restored EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Array Controller Redundancy has been Restored NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number HP_DeviceIndication Array Controller Model string DeviceModel HP_DeviceIndication: Controller Battery Status Change - OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Batter
SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) be
AlertingManagedElement WBEM Path to SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 7 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check battery operation, allow time to the battery to be fully charged.
RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example: Smart Arra
ProbableCause 92 (battery failure) ProbableCauseDescription Controller Battery Status Changed to Failed NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
HP_DeviceIndication: Controller Cache Status - OK Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Cache status has changed from non-OK to OK. AlertingManagedElement WBEM Path to SMX_SAArrayController class.
SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array Controller Serial Number ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3
AlertType 5 (Device Alert) EventID 10 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example: Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer HWSerialNumber Array
ProbableCause 35 (Performance Degraded) ProbableCauseDescription Array Controller Cache Status Changed to Permanently Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
HP_DeviceIndication: Enclosure Power Supply Status changed to Non Redundant Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to non-redundant.
SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example: Port 1I Box 1 Enclosure Serial Number HWSerialNumber HP_DeviceIndication Enclosure Model string DeviceModel HP_DeviceIndication: Enclosure Power Supply Status changed to Redundant Degraded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of ind
OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed from non-OK to OK. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 307 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array ( RecommendedActions No action is recommended.
BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Warning Condition EventCategory 24 (Primary Storage Cooling) ProbableCause 51 (Temperature Unacceptable) ProbableCauseDescription Temperature Status Changed to Warning Condition NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
HP_DeviceIndication Enclosure Model string DeviceModel HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Critical Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical.
SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDo
AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 304 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example: Port 1I Box 1 Enclosure Serial Number HWSerialNumber HP_DeviceIndication Enclosure Model string DeviceModel HP_DeviceIndication: Enclosure Fan Status changed to
NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
The following table lists the properties implemented. Any combination of the following applicable descriptors could be used to better define the device location.