HP Insight Management WBEM Providers for MS Windows 9.1 Release Notes

2 What's new in this release
The following features are supported in the current release of WBEM Providers:
DMTF CIM Schema synchronization to version 2.28.0
Solid State Drive support for SAS Controllers
Support for HP Smart Drive Carrier authentication for SAS controllers
New OS and platform support. For more information about the new OS and platform supported,
see the HP Insight Management WBEM Providers Support Matrix document available at the
following location:http://h18004.www1.hp.com/products/servers/management/wbem/
documentation.html.
Known issues and limitations
This section provides a list of known problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.
Network connectivity lost during WBEM installation
WBEM Provider installation hangs inconsistently when installed using tools such as the HP
Rapid Deployment software. This issue is caused when WBEM Provider enters a non-operational
mode during installation due to certain memory race conditions.
Severity: High
Corrective Action: Cancel the installation manually and restart the server.
Updated version for Power Controller not displayed
On HP Proliant server, due to software/key values not available from HP WBEM Providers,
the updated version for Power Controller is not displayed in inventory under System
Management Home Page (SMH)HomeVersion ControlHP Version Control Agent.
Severity: High
Corrective Action: None
Cooling page has no information of fans for G6 server with ILO2
On HP ProLiant G6 servers with iLO2, fan-related instance and indication information are not
available from HP Insight Management WBEM Providers.
Severity: High
Corrective Action: Change the management source from WBEM to SNMP to obtain fan-related
information.
Online help search displays incorrectly
In the Japanese online help for Storage, the search results page does not display in the proper
format.
Severity: High
Corrective action: None
Online help search fails at second attempt
In the Storage online help Search page, when you provide the same keyword or string in the
Search field for the second time, the search fails.
Severity: High
Corrective action: None
Known issues and limitations 5