HP Insight Management WBEM Providers 9.5 Release Notes
1 What's new in this release
The following features are supported in the current release of WBEM Providers:
• Supports Microsoft Windows Server 2012 R2
• Supports the following servers:
DL580 Gen8◦
◦ SL6700
◦ BL660Gen8
◦ DL560Gen8
◦ DL360e
◦ DL380e
◦ BL420c
◦ SL4540 Gen8
• Supports Smart Array Controller encryption status
• Supports Unified Extensible Firmware Interface Platforms
Known issues and limitations
This section provides a list of known problems and limitations as known to HP at the time of
publication. If workarounds are available, they are included.
• Network connectivity lost during WBEM installation
WBEM Provider installation hangs inconsistently when installed using tools such as the Insight
Control Server Deployment. This issue is caused when WBEM Provider enters a non-operational
mode during installation due to certain memory race conditions.
Severity: High
Corrective Action: Cancel the installation manually and restart the server.
• iSCSI information not available in HP System Management Home Page
On HP ProLiant server with “HP Insight Management WBEM Providers version 9.5.0.0”
installed, HP Insight Management WBEM Providers may not show iSCSI Initiator information
in the HP System Management Homepage, when you click the iSCSI Initiator link in the left
panel under System Management Home Page (SMH)→Home→Storage→ISCSI Initiator
Severity: High
Corrective Action: The other management data source SNMP can be used to get the information
for iSCSI Initiator in HP System Management Home Page.
4 What's new in this release