HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 21-29 HP_TapeDriveDeviceIndication: Drive status changed to Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
HP_HardwareIndication
HWFirmwareVersion Enclosure F/W version string (It must match the
HP_TapeDriveFirmware.VersionString)
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number (It must match the
HP_StorageEnclosure.SerialNumber)
HP_DeviceIndication
DeviceModel Enclosure Model string
HP_TapeDriveDeviceIndication
21-4-4 Drive status changed to Failed
Table 21-30 HP_TapeDriveDeviceIndication: Drive status changed to Failed
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance