HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 17-76 HPSCSI_DeviceIndication: Temperature sensor status change OK
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Enclosure firmware version string
HWLogicalLocation Enclosure Location string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17-4-16 Temperature sensor status change Warning Condition
Table 17-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description The SCSI Storage enclosure temperature is outside of
normal operating range
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 24
ProviderName HP SCSI
RecommendedActions Ensure server cover is properly installed. Ensure all
empty disk drive bays are filled with drive covers.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication