HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 17-66 HPSCSI_DeviceIndication: Physical Drive status - Missing was OK
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
DeviceModel Disk Model string
17-4-6 Physical Drive status—Missing was FAILED
Table 17-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive that was located in the system and
had a status of failed has been removed
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 10
ProviderName HP SCSI
RecommendedActions Check for this disk to have been removed
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive missing was failed
EventCategory 6 (Primary Storage)
ProbableCause 73 (Element Missing)
ProbableCauseDescription Missing Physical Drive was Error.
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication