HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 16-95 HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
2-4-20 Enclosure Fan Status change to Failure
Table 16-96 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan Status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 306
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.