HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
2-4-19 Enclosure Fan status changed to Degraded
Table 16-95 HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan status has changed to
Degraded. An enclosure has detected there might be a
problem with one or more of the fans.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 305
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Fan status Degraded
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan failure)
ProbableCauseDescription Fan Degraded
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication