HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 16-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Predictive
Failure.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 204
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive predictive failure
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Physical Drive Predictive Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication