HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 16-79 HPSAS_DeviceIndication: Physical Drive status OK
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
2-4-4 Physical Drive status ERROR
Table 16-80 HPSAS_DeviceIndication: Physical Drive status ERROR
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Error.
AlertingMangedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 202
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Error
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)