HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 15-137 HPSA_DeviceIndication: Enclosure Fan status changed to Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
15-4-44 Enclosure Fan status change to Failure
Table 15-138 HPSA_DeviceIndication: Enclosure Fan status changed to Failure
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description Enclosure Fan Status changed to a status of Failure.
Enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure normal
operation.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 306
ProviderName HP Smart Array