HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
15-4-41 Enclosure Temperature sensor Status Changed
to Critical
Table 15-135 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description Temperature sensor Status changed to a status of
Critical. Enclosure temperature is reaching maximum
allowed temperature for normal operation, shutdown is
imminent. Action is required before loss of data occurs.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 309
ProviderName HP Smart Array
RecommendedActions Verify fan and power supply operation for enclosure.
Verify ambient room temperature is within guidelines.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor Status changed to Critical.
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51 (Temperature Unnacceptable)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116