HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 15-134 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Temperature sensor Status changed to Warning
Condition. This indicates the enclosure temperature is
above normal, otherwise enclosure is still operating
normally.
AlertingMangedElement WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 308
ProviderName HP Smart Array
RecommendedActions Verify fan and power supply operation for enclosure.
Verify ambient room temperature is within guidelines.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Temperature sensor Status changed to Warning
Condition.
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>