HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
15-4-33 Controller ASIC encryption self test status
changed to Failed
Table 15-119 HPSA_DeviceIndication: Controller ASIC encryption self test status changed to Failed
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array Controller ASIC encryption self test
status has changed to Failed because of ASIC
encryption self tests failure
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 14
ProviderName HP Smart Array
RecommendedActions Check the controller encryption error code and run
diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array controller ASIC encryption self test status failed
EventCategory 6 (Primary Storage)
ProbableCause 24 (I/O device error)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>