HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 15-128 HPSA_DeviceIndication: Controller Cache status—Failed
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Error)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array Controller Cache Status has changed to
Failed.The
controller has detected a problem with the cache and
has failedthe cache.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 11
ProviderName HP Smart Array
RecommendedActions Check the cache controller error code and run
diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array controller cache status failed.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>