HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to New Logical Drive Key
Rekey In Progress
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
HWLogicalLocation Logical drive number & RAID Level.
For example, LogicalDrive 1 (RAID 1+0).
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationStatus values for Storage Volume
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-20 Controller Status Changed to OK
Table 15-118 HPSA_DeviceIndication: Controller status changed to OK
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degdaded/Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Array Controller Status has changed to a status of OK.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
ProviderName HP Smart Array