HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
15-4-13 Logical Drive Status Changed to Not Yet
Available
Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Not Yet Available
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed to Not Yet
Available.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 107
ProviderName HP Smart Array
RecommendedActions Check status of Logical drives. Degraded status may be
caused by not yet available state.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical drive in not yet available state.
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
For Windows 2012 R2 : 116