HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet
HP Confidential
Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-9 Logical Drive Status Changed to Degraded
Table 15-116 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded)
IndicationTime Time of indication
CIM_AlertIndication
Description A Logical Drive is in a degraded state. Device is still
servicing I/O but redundancy may be degraded or
lost.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 103
ProviderName HP Smart Array
RecommendedActions Check status of physical drives. Degraded status may
be caused by failed or missing physical drives, or a
data recovery operation on one or more physical
drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical Drive in degraded state.
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)