Table 15-44 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer HP
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
15-4-5 Physical Drive Status Changed to PREDICTIVE
FAILURE – Solid State Wear Out
Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Due to Solid State wear out a physical drive status has
changed to Predictive Failure .
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 311
ProviderName HP Smart Array
RecommendedActions Replace drive immediately to avoid loss of data
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical Drive status PREDICTIVE FAILURE
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)