HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
Table 15-44 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
VariableNames[0]: FailureDescription
VariableNames[1]: LastFailureDescription
VariableNames[2]: DriveInterface
VariableTypes
VariableTypes[0]: 1 (String)
VariableTypes[1]: 1 (String)
VariableTypes[2]: 4 (uint16))
VariableValues
VariableValues[0]: Short Description of failure
VariableValues[1]: Short Description of last failure
VariableValues[2]: HPSA_DiskDrive.DriveInterface
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)