HP Insight Management WBEM Providers 9.5 for Microsoft Windows Data Sheet

HP Confidential
15-3-18 HPSA_StoragePool
HPSA_StoragePool represents any concrete storage pools created on an array controller. There is one
instance per RAID set.
Table 15-19 Class: HPSA_StoragePool (CIM_StoragePool)
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_ManagedElement
ElementName Controller name and location: pool identifier (for
example, Smart Array in Slot 3: Array 0)
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID Opaque key
PoolID Controller serial number:<n>, where <n> is the array
number as supplied from API
Primordial Always set to FALSE
RemainingManagedSpace Remaining raw space in current pool
TotalManagedSpace Total raw space managed by this pool
HPSA_StoragePool
15-3-19 HPSA_MediaAccessStatData
HPSA_MediaAccessStatData represents the Monitoring and Performance data counters on HP Disk
Drives.
Table 15-20 Class: HPSA_MediaAccessStatData (CIM_MediaAccessStatData)
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_ManagedElement
ElementName Disk location (For example, Port: 1E Box 1 Bay: 5)
CIM_StatisticalData
InstanceID Opaque key
SampleInterval 0
CIM_MediaAccessStatData
HPSA_MediaAccessStatData
AbortedCommands See HP Smart Array Profile
BadTargetErrors See HP Smart Array Profile