Table 13-26 HP_AlertIndication: Ethernet Team Redundancy Decreased
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
13-4-4 Ethernet Team Full Redundancy Restored
Table 13-27 HP_AlertIndication: Ethernet Team Full Redundancy Restored
Pro
p
ert
y
name Pro
p
ert
y
im
p
lementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description The Ethernet Team has transitioned from Redundancy
Lost or Degraded Redundancy to Fully Redundant, due
to a failed or degraded team member recovering full
functionality. The team and all team members are
operating as configured.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet) reporting full redundancy
restored.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 2 (Communications Alert)
Event Id 15
ProviderName HP Ethernet
RecommendedActions[] None
SystemCreationClassName CreationClassName of the computer system generating
the indication